Continuous Emission Monitoring System
Agasthya 2013 Series
BI 7000 – NPL Certified, CPCB Compliance

The Agasthya 2013 Series Continuous Emission Monitoring System BI 7000 is designed in compliance to emission norms to measure gases pollutants emitted by various process industries and to meet the needs of organizations requiring cost effective and reliable multiple gas analyzer solutions.

BI 7000 is TUV certified for CE mark & Performance as per EN15267 standard.

The technology employed are of maximum reliability and accuracy to ensure high degree of performance & long life.

BI 7000 is ideal solution to protect initial investment & can adapt to any process application with modular design & can house up to eight gas sensors with scalable ranges for each gas.

Manufactured for use in hostile or friendly environments the BI 7000 Continuous Emission Monitoring System maintains high levels of gas selectivity, all packed into a robust, attractive, industrial enclosure.

Continuous Emission Monitoring System - BI 7000 NDUV
  • Tried and tested technology with proven reliability
  • Scalable ranges available for each gas
  • 5.6” Smart Touchscreen Display
  • The best price performance on the market – designed with user requirements foremost in mind
  • Isolated 4-20 mA analog output for each gas
  • RS 485, MODBUS protocol
  • High / Low Gas, low flow & other programmable events available
  • Highly efficient automatic purge & drain system
  • Inbuilt interface for Remote Calibration Unit
  • Auto & semi auto calibration facilities

Analyzer Specification

  • Sensor Technology
    • Non Dispersive Infrared Absorption (NDIR)
    • Non Dispersive Ultraviolet Absorption (NDUV)
    • Tunable Diode Laser Spectrometry (TDLS)
    • Zirconia (ZrO2)
    • FID (Flame Ionization Detector)
  • Measurement Gas
    • CO
      0-5000 ppm
    • NO
      0-1000 ppm
    • SO2
      0-1000 ppm
    • CO2
      0-20%
    • HC
      0-5%
    • NO2
      0-1000 ppm
    • Cl2
      0-30 ppm
    • H2S (NDUV)
      0-50 ppm
    • HF
      0-30 ppm
    • HCl
      0-200 ppm
    • NH3
      0-500 ppm
    • H2S (TDLS)
      0-200 ppm
    • O2
      0-30%
    • THC
      0-1000 ppm
    • TOC
      0-1000 ppm
    • VOC
      0-1000 ppm
  • Resolution
  • 0.1% (HC, CO2, O2)
    1 ppm (Other Gases)
  • Accuracy
  • ±1% FSD
  • Repeatability
  • 1% FS
  • Zero Drift
  • <±1% per week of Span
  • Span Drift
  • <±1% per week of Span
  • Response
  • T90 < 200 sec
  • Operating Temperature
  • 4°C to 65°C
  • Analog Output
  • Isolated and linear 4-20mA analog output for each gas
  • Digital Communication
  • RS 485, Supports MODBUS Protocol
  • Relay Output
  • 2 Nos. Potential free contact for alarms
  • Power Supply
  • 110/230 VAC, 50 Hz
  • Programmable Events
  • High / Low Alarms
  • Calibration Facilities
  • Auto & Semi Auto Calibration

CEMS Specification

Heated Sampling Probe

  • Operating Temperature
    : Max. 400ºC
  • Mounting
    : Flange Type
  • Max. Working Pressure
    : 6 bar
  • Voltage
    : 110/230 V, 50/60 Hz
  • Heating
    : Self-regulating +180ºC
  • Ambient Temperature
    : -20 to +80ºC
  • Dust Concentration
    : Up to 5 g/m³
  • MOC
    : SS 316

Heated Sample Gas Line

  • Process Tube
    : PTFE / SS
  • Process Tube Size
    : 1/4 inch OD
  • Heating Element
    : Constant watt type
  • Thermal Insulation
    : Non-Hygroscopic Fiber Glass
  • Outer Sheath
    : Extruded UV Resistant FRLS PVC
  • Operating Voltage
    : 230 V AC
  • Watt Density
    : 45 W/m
  • Length
    : To be specified by client
  • Max. Operating Temperature
    : 200ºC
  • Temperature Sensor
    : In built RTD
  • Process Connection
    : Flanged Type
  • Power/Control Connection
    : Lead cable (3 Wire), 2 Meter for both power & control

Sample Conditioning Unit

  • Smart unit
  • Aspirator/Pump for sampling flue gas
  • Pre and post cooler fine filters to remove drain, dust and mist in sample gas
  • Auto drain and auto purging (blow back) facilities
  • 2 way solenoid valves for switching, sampling, purging, draining and calibration
  • Flowmeter to regulate and monitor the flow of sample gas
  • Drain pump for continuous removal of condensate

NOx Converter

  • Capability
    : High NO2 conversion capability
  • Enclosure
    : 19 inch Housing
  • Working Temperature
    : 400ºC
  • Sample Gas Pressure
    : Up to 1.5 bar
  • Warm-up Time
    : 30 min
  • Sample Gas Flow
    : Up to 120 l/h
  • Sample Gas Temperature
    : 5 to 80ºC
  • Ambient Temperature
    : 5 to 50ºC
  • Connection
    : 1/4″ F NPT
  • Materials
    : SS316, PTFE, Viton

Cabinet

  • Industrial cabinet meets IP54 standard
  • Inbuilt air conditioning system
  • Automatic cabinet illumination when door opens
  • Earthing bar assembly
  • 180 degree door opening
  • Standard Dimension: 1500 (H) x 600 (W) x 800 (D) mm
  • Purge Panel available on request for Hazardous Area

Remote Calibration System

  • Panel with certified cylinders and automation for calibration
  • Software with User Interface for remote calibration
  • Compatible to interface with any Server
  • Server Data Connectivity to CPCB & SPCB available
  • Aluminium
  • Cement
  • Distillery
  • Chlor Alkali
  • Fertilizers
  • Iron & steel
  • Oil refinery
  • Petrochemical
  • Pharmaceuticals
  • Power Plants
  • Thermal Power Plants
  • Pulp & paper
  • Sugar
  • Zinc
  • Copper
  • Boiler
  • Biomedical waste Incinerator
  • Common Hazardous Waste Incinerator

    Related Products