Biogas Analyzer
Agasthya 2013 Series
BI 7110

Features

  • 32-Bit Cortex-M3 ARM Processor
  • 5.7″ QVGA TFT Touch Screen Display
  • Built-in sample pump, pre-filter, filters and flow meter
  • Relays for high & low alarms
  • Long life Electrochemical O2 sensor
  • Automatic moisture removal system included
  • RS485, supports MODBUS protocol
  • Temperature controlled sensors for maximum stability
  • Isolated 4-20 mA analog output for each gas
  • Infrared sensor for reliable measurement of CO2 and CH4
  • Cabinet positive-pressure system to minimize the corrosive effects hydrogen sulfide (H2S) on cabinet electronics & sensors
  • PTFE tubing and corrosion-resistant components
Supporting Renewable Energy in India with Landfill Gas Analysers

Continuous Biogas Gas Measurement

The BI7110 biogas analyzer is designed to measure CH₄, H₂S, CO₂ & O₂ in bio gas streams from biogas plants and industrial sites

Moisture Removal & Sample Conditioning

The BI7110 bio gas analyzer uses continuous moisture removal with pre-filter, pump, and flow meter for stable performance in wet gas conditions

Multi-Gas Sensing & Outputs

This gas analyzer includes long-life CH₄, CO₂ & O₂ sensors with alarm relays and 4–20 mA outputs for each gas measured

Industrial & Waste Management Applications

It functions as a biogas analyzer 7110 for continuous bio gas measurement in digesters, reactors, wastewater and landfill gas systems

Reliable Monitoring for Energy & Agriculture Plants

The BI7110 works as an industrial biogas analyser for renewable energy facilities, bio gas monitoring instrument for agriculture digesters, and biogas analyzer for waste-to-energy plants

  • Method of Detection
  • NDIR infrared sensor for CO2, CH4
    Electrochemical sensor for O2
    Electrochemical sensor for H2S
  • Ranges Available
    • O2
      0-25% Resolution: 0.10%
    • CO2
      0-10%, 0-50%, 0-100%, Resolution: 0.10%
    • CH4
      0-50%, 0-70%, 0-100%, Resolution: 0.10%
    • H2S
      0-200 ppm, 0-2500 ppm, Resolution: 1 ppm
  • Accuracy & Repeatability
  • ± 2% of reading for all gases
  • Drift
  • Less than 2% of full scale per month
  • Response Time (T-90)
  • 20-30 seconds
  • Ambient Temperature Range
  • 4 to 50°C
  • Power
  • 80 to 230 VAC 50 Hz
  • Output
  • Isolated 4-20 mA standard
    RS 485, supports MODBUS protocol
  • Relay Output
  • 2 Nos. of potential free contacts
  • Biogas plants
  • Landfill sites
  • Water Treatment
  • Sludge Digestion
  • Biomethane Production
  • CDM Project
  • Anaerobic Digestion
  • Other Fermentation Processes