Insitu Zirconia Oxygen Analyzer
Agasthya 2005 Series
BI 2000

Features

  • Long Life Zirconia Sensor
  • Automated Purge System
  • Multi point Calibration
  • Zero Maintenance
  • Thermal shock proof
  • Field repairable with ease
  • Designed to withstand flue gas temperature
  • Field repairable parts
  • Standard & customized probe lengths available
  • Multiple probe material options available for application suitability
  • HART communication along with RS485 Digital and Analog signals
  • Heater Thermocouple External to the Sensor
Zirconia O2 analyzer BI 2000 for industrial gas monitoring

Real-Time Combustion Oxygen Measurement

The BI 2000 Insitu Zirconia Oxygen Analyzer provides accurate excess O₂ readings using a sensor-at-tip zirconia O2 analyzer design

Industrial Gas & Emission Monitoring

This zirconia analyzer BI 2000 for industrial gas analysis functions as a zirconia O2 analyzer for emission control systems

Optimized for Process Industries

It operates as an insitu zirconia oxygen analyzer for process industries and an oxygen analyzer for continuous flue gas monitoring

Suitable for Chemical & Energy Plants

The BI 2000 works effectively as a gas analyzer for chemical and petrochemical plants and an O2 analyzer for refineries and waste-to-energy plants

Rugged Probe for Combustion Efficiency

Its durable sensor serves as a zirconia probe for combustion optimization and an industrial oxygen analyzer for process heaters

Insitu Oxygen Sensor Specification

  • Range
  • 0–25% O₂ Programmable
  • Accuracy
  • <±0.75% of FS
  • Resolution
  • 0.01%
  • Repeatability
  • ±0.5% of FS
  • Response Time
  • T90 < 3 sec

  • Ambient Temp
  • -20 to +150°C
  • Probe Junction Box Rating
  • IP66
  • Probe Junction Box
  • Die Cast Aluminium
  • Mounting
  • Flange mounting

  • Probe MOC
  • SS316 / SS310 / Alumina
  • Probe Length in mm
  • 500, 750, 1000, 1500, 2000, 3000, 3600, 4200, 5400
    (Abrasive shield / protection tube available)
  • Flange MOC
  • SS316
  • Flange Size
  • 3″ ANSI B16.5 150#. Other flanges on request.
  • Diffusion Element
  • Sintered steel, unbreakable ceramic (Filter optional)

O2 Electronic Unit Specification

  • Operating Temp
  • 0 to +70°C
  • Storage Temp
  • 0 to +70°C
  • Ambient Humidity
  • 0 to 95% RH (non-condensing)
  • Warm-up Time
  • Default 30 min (1–99 min user configurable)

  • Power Supply
  • 110VAC / 230VAC
  • Display
  • 2.4 inch or 3.5 inch TFT LCD display with 4 keys
  • Calibration Mode
  • Auto / Semi Auto / Manual — Single, Two & Multi (5-point)
  • Calibration Gas
  • Zero Gas: 0.25–2% O₂ | Span Gas: 10–21% O₂
  • Self-Diagnosis
  • Sensor fail, heater fail, electronics fail, temp sensor fail

  • Analog Output
  • Isolated 4–20mA (Max load 550 Ω)
  • Digital Output
  • 4 relay outputs (1 alarm relay)
  • Digital Communication
  • RS485, MODBUS RTU / HART 5

  • Mounting
  • Wall mount
  • Enclosure
  • Mild Steel / Die Cast Aluminium
  • Enclosure Rating
  • IP65, IP66
  • Dimension
  • 300mm x 210mm x 300mm (L×W×H), other options available
  • Cable
  • 6-core screened cable

In-situ Oxygen Analyzers are used to optimize combustion in industrial and large commercial applications such as Boilers, Incinerators, Reheating Ovens, Melting Furnaces, Fired Heaters, and Kilns. They improve safety and combustion efficiency, resulting in reduced energy consumption, lower emissions, and enhanced operational performance.

Industries that use In-situ Oxygen Analyzers

  • Power Plants – Gas and Oil-fired Boilers, Inert Gas Generators
  • Oil Industry – Incinerators and Process Heaters
  • Gas Industry – Gas processing plants, transmission lines & gathering systems
  • Petrochemical Refineries & Chemical Processing
  • Cement Kilns & Clinker Production
  • Thermal Energy & CHP Systems
  • Ceramics & Glass Furnaces
  • Pulp & Paper Drying Processes
  • Municipal & Industrial Waste Incineration
  • Metal & Steel Reheating / Heat-treatment Furnaces

    Related Products