System Components
1. Probe
It is a gas sampling probe. Removes dust in sample gas. Has an inbuilt temp sensor for flue gas temperature measurement.
2. Sampling module
The sampling module contains the following components
Diaphragm pump to extract sample
Flowmeter and needle valve to regulate and monitor the flow of sample gas
Fine Filter to removes drain, dust and mist in sample gas.
Drain pot to collect condensate
Technical Data
Gas Conditioning Type |
CCS8 |
Sample inlet temperature |
max. 1000°C |
Gas flow rate |
max. 350Nl/h |
Ambient temperature |
+5°C up to +40°C |
Number of gas outlets |
one (option two) |
Medium connections |
¼" tube connections |
Material of parts being in contact with the medium
|
stainless steel, PTFE,
|
Power supply
|
Battery Operated
|
Electrical connection
|
Terminals 6mm 2
|
Casing dimensions (H x W x D)
|
350mm x 350mm x 300mm
|
Weight
|
approx. 5.0kg
|
|